Home   |   About Us   |   Contact Us   |   Trade Prices   |   Delivery   |   View Checkout   |   
Creative Pumps Thawte Logo
bottom-footer

Deluxe Stainless steel Projecting sheet spillways

Back entry deluxe projecting spillway Bottom entry deluxe projecting spillway
 Standard back water inlet
1 1/4" BSP female thread ready to take a hose tail or elbow.
  Standard bottom water inlet
1 1/4" BSP female   thread ready to take a hose tail

Spillway installation choices

        Typical istallation of deluxe projecting spillway - Back entry                  Bottom entry of deluxe projecting spillway
Typical spillway installation....  When the wall is thick eg. Block or brick etc  In this case a back water inlet choice should be chosen. Typical spillway installation....  When the wall is thin eg. Blue board, plywood, glass etc. In this case the bottom water inlet choice should be chosen.

Pump installation choices - In pond or outside pond

Pond pump mounted in pond Pump mounted outside of pond
Typical pump installation....  A submersible pump is positioned in the pond with water pumped through the pond wall and up to the spillway.
Note: This is the best way to set up your pump from the stand point of the pumps performance, as any pump noise (mostly associated with less expensive pumps) is muffled, the pump is kept cooler and therefore will have a longer life, in most cases a pre filter can be attached to the pump.
Optional pump installation ...  A pump suitable for dry mounting is positioned behind the pond and the water is then pumped up to the spillway.
Note: This arrangement allows the pump to be hidden, however the benefits mentioned in the in-pond option such as noise, cooling are lost.
Spillway in use with pond pressure filter Filter system?
If the pond is large enough you may wish to consider some for of filtration. Shown here is an external pressure filter, however in pond filters are also available.
Typical setup of pump in pond feeding spillway
Showing a side and front view of the Sheer descent (Projecting sheet) in action with a thick wall, however, wall thickness down to a few mm is fine.
Neat and tidy

A method of getting both the electrical cable (with plug intact), and the hose out of the pond.
  At the same time the pump can be removed for servicing without the plug being cut off or having the cord and hose over the ponds edge.


Example of how to run power lead out of pond

Hansen fittings for running water thru the walls of ponds and features
See our plumbing section for more details and choices of Hansen through wall fittings
 

Hansen through wall fitting .... for passing hose through the pond wall, 5 thread sizes from 1/2" to 2" BSP and a wide choice of lengths and matching barb hose fittings look at our plumbing section or call for more details. Each fitting Rubber washers for water tight seals.