Choosing
your pump
For both AquaFlo &
Aqua-rt spillways
|
PUMPS: How to choose :
A projecting sheet spillway requires a flow of at least 700 Litres per hour for every 100mm
of spillway width.
While a sheet descent sheet spillway requires a flow of at least
350
Litres per hour for every 100mm
of spillway width. This flow rate is measured at the spillway, therefore in
choosing the pump, the distance* between the surface of the water and the
spillway is a factor that only you will know. We have therefore made a
number of suggestions below based on about 1.0m mounting, covering a variety
of price points. The (list starts with the best quality and works right).
*The higher the water is being pumped, the larger the pump must be, also on
2 and 3 inlet spillways the flow must be higher because of the tee that is
required in the plumbing.
Please read the hints section at bottom of
page
|
Potential pond pumps*
When used as a
sheet descent
(softly down the wall) |
Spillway
length |
Min
flow rate required at the spillway -
litres per hour |
Pump
Location |
*Based on about 1000mm
mounting height**
**Head,
the distance between the top of the water in the pond and the mounting
height of the spillway. |
|
300 |
1,050 |
Inside
pond |
Pondmate 2400 Max
Flo 3500
Eden
135
Oase Neptun
2000 |
|
Outside pond |
Pondmate 2400
Oase Neptun
2000 |
|
600 |
2.100 |
Inside
pond |
Pondmate 3500
Oase Neptun
3000 |
|
Outside pond |
Pondmate 3500 Oase Neptun
3000 |
|
900 |
3,150 |
Inside
pond |
Pondmate 4800
Max
Flo 6000
Oase Neptun
4000
Little Giant WGP55
|
|
Outside pond |
Pondmate 4800 Oase Neptun
4000 |
|
1200 |
4,200 |
Inside
pond |
Pondmate 6000
Oase Neptun
5000 |
|
Outside pond |
Pondmate 6000 Oase Neptun
5000 |
|
1500 |
5,250 |
Inside
pond |
Pondmate 6000
Max
Flo 7500**
Oase Neptun
6000
|
|
Outside pond |
Pondmate 6000 Oase Neptun
6000 |
|
1800 |
6,300 |
Inside
pond |
Pondmate 8500
Max
Flo 9000**
Oase Neptun
9000
Little Giant WGP65
|
|
Outside pond |
Pondmate 8500 Oase Neptun
9000 |
|
2400 |
8,400 |
Inside
pond |
Pondmate 10000
Max
Flo 11000**
Oase Neptun
9000
Little Giant WGP75
|
|
Outside pond |
Pondmate 10000 Oase Neptun
9000 |
|
**See hint 6 at bottom of page regarding
this pump for the above spillways |
|
Potential pond pumps*
When used as a
projecting sheet (sheer descent) (not
touching the wall) |
|
Spillway
length |
Min
flow rate required at the spillway -
litres per hour |
Pump
Location
|
*Based on about 900mm
mounting height**
**Head,
the distance between the top of the water in the pond and the mounting
height of the spillway. |
|
300 |
2,100 |
Inside
pond |
Pondmate 3500
Oase Neptun
3000 |
|
Outside pond |
Pondmate 3500
Oase Neptun
3000 |
|
600 |
4,200 |
Inside
pond |
Pondmate 4800
Max
Flo 6000** Oase Neptun
5000 |
|
Outside pond |
Pondmate 4800 Oase Neptun
5000 |
|
900 |
6,300 |
Inside
pond |
Pondmate 8500 Max
Flo 7500**
Little Giant WGP65 |
|
Outside pond |
Pondmate 8500
Oase Neptun
9000 |
|
1200 |
8,400 |
Inside
pond |
Pondmate 10000 Max
Flo 11000**
Oase Neptun
9000
Little Giant WGP75 |
|
Outside pond |
Pondmate 10000
Oase Neptun
9000 |
|
1500 |
10,500 |
Inside
pond |
Pondmate 15000
Oase Neptun
12000
Little Giant WGP95 |
|
Outside pond |
Pondmate 15000 |
|
1800 |
15,300 |
Inside
pond |
Pondmate 18000
|
|
Outside pond |
Pondmate 18000 |
|
2400 |
16,800 |
Inside
pond |
Oase Profinaut 21
|
|
Outside pond |
Oase Profinaut 21 |
|
**See hint 6 at bottom of page regarding this
pump for the above spillways |
|
Aussie says
 |
**Head,
the distance between the top of the water in the pond and the mounting
height of the spillway.
Tip
1: If being used as a projecting
sheet effect, never mount higher
that 900mm above the water. The further the water
drops, the narrower it becomes due to
surface tension. The drop in
the photo's above is .9m to give you an idea. Another way to understand this
tapering effect is that for every 50cm of drop,
the width of the sheet of water narrows by about 100mm.
After about 90cm of drop the sheet starts to break up.
Hint 2: Any elbows or tees in the system will reduce flow.
On the 2
inlet model spillways, it may be desirable to use two pumps, this will avoid
the need for a tee.
Hint 3: Glass .. When water is run
down glass, to improve water flow and maintain it's full width you should
angle the wall between 2 to 5 degrees
Hint 4: Acrylic .. When water is
run down Acrylic, to improve water flow and maintain it's full width you
should angle the wall between 5 to 7 degrees
Hint 5:
How to neatly get the electrical cable from the pump and the water tube out
of the pond cleanly and allow for service.
Click here
Hint 6: Best pump type The best pump for this type of spillway is one
that will not allow particles to block or partial block the water delivery
slot. This makes the Pondmate range up to the 8500 model ideal as this pump
includes a foam pre filter.
The best quality pump we have, the Oase Neptun does not have a pre filter,
however, a foam block filter can be added.
Pump like the Laguna Maxflo are intended as a pump for a filter and
therefore will take in lots of particles and debris. The only solution to
make this pump suitable is to cover the pump cage with fly screen wire or
similar. |
|
|
|
|